Figure 11 save a trace – Bird Technologies AT-800-Manual User Manual
Page 47

Measure Match
29
Example - If a trace is displayed in VSWR, it
can be compared to a trace displayed in
%Match. The frequency band of the new trace
can be changed, to effectively zoom in on a par-
ticular section of the saved trace. This may be
helpful in pinpointing a problem area in a
failed limit test.
Figure 11 Save a Trace
The desired units, band, and scale should be selected.
This will enter the single hold mode and the trace to be
stored should be displayed.
If continuous sweep type is selected, the trace displayed
when saved will be stored.
1. Press the MENU key.
2. Press the MEAS MATCH key.
3. Press the SWEPT FREQ key.
4. Press the TRACE key.
5. Press the SAVE TRACE key.
6. Press a REG-n key that has empty displayed.
AMPS
TxRx
Mobile
Reg-1
Empty
Reg-2
Empty
Reg-3
Empty
Reg-5
Empty
More
Save
VSWR
2.0
1.0
824.01
MHz
893.97
1.35
858.27 MHz
<HOLD>