Figure 2 bds receiver mounting holes, Installing the sensor, Figure 3 sensor cable connections – Bird Technologies BDS-Manual User Manual
Page 20

6
Figure 2 BDS Receiver Mounting Holes
Installing the Sensor
1.
Connect the sensor RF In connector to the feed side of the host RF source cable.
2.
Connect the sensor RF Out connector the load side of the host RF source cable.
Figure 3 Sensor Cable Connections
Item
Description
1
Mounting feet, rubber
2
Mounting holes, 6-32 threaded
CAUTION
Bending RF cables can cause damage. When routing RF cables, the minimum
bend radius is 2 inches (25.4 mm). Do not bend the cables more than the
minimum bend radius. Failure to comply may result in permanent damage to the
cable and reduced equipment performance.
1
1
2
2
Item
Description
1
RF output connector
2
RF input connector
3
Current connector, SMA standard polarity
4
Temperature / data connector, 7 pin
5
Voltage connector, SMA reverse polarity
1
2
5
3
4
Note: Standard BDS
sensor shown.