Installation – Bird Technologies 8251D208 User Manual

Page 19

Advertising
background image

Chapter 3

Installation

CAUTION

This equipment is designed for operation in a

horizontal position only, with mounting brackets down.

Do not operate in any other manner.

The load is to be installed, and operated in a horizontal posi-

tion. The load is shipped horizontal, and normally stands on

its base brackets.

The load may be used for portable operation and stand free,

or it may be secured to a bench top or other flat surface for a

fixed installation. Mount the load with four screws of up to

1/4 inch diameter. Fasten the screws through the four 9/32

inch holes in the mounting brackets that arranged in a 5-1/8

inch x 15 inch (130.2 x 381 mm) rectangle.

Location

For operation above 300 watts allow at least six inches (153

mm) of clearance on each side. Operate the load in a hori-

zontal position only, with the handle on top.

Shipping and

Vent Plugs

WARNING

The vent plug must be used at all times when the unit

is in operation or cooling. Failure to do this could

result in damage to the equipment and endanger the

operator’s safety. Be sure to check this plug.

CAUTION

Do not leave out the O-Ring seal, P/N 5-504 when

interchanging the vent and shipping plugs.

Before placing the unit into operation, remove the shipping

plug on the top of the radiator and replace with the vent

plug supplied. Refer to figures 1 and 2 for identification of

the plugs. Don’t forget to use the O-Ring seal, P/N 5-504.

The shipping and vent plugs are connected with a short

length of bead chain to prevent the mislaying or loss of the

unused plug.