Bird Technologies 8251D208 User Manual

Page 20

Advertising
background image

Connecting to

the

Transmitter

Connect the load to the transmitting equipment under test

with 50 ohm coaxial cable (RG-8A/U, RG-9/U, RG-213/U or

equivalent). After the transmitter has been connected to the

load, proceed according to the transmitter manufacturer’s

instructions. When reconnecting the antenna, it may be nec-

essary to slightly readjust the transmitter due to possible

differences in VSWR between the load and the antenna sys-

tem.

The 1-5/8 inch EIA flange connector is fastened to the trans-

mission line by four 5/16-18 x 1-1/2 bolt sets. The center con-

ductors must be joined with a bullet for 50 ohm 1-5/8 inch

coaxial lines. Bird P/N 4712-020 Bullet Kit includes the bolt

sets, O-Ring, and center conductor bullet.

+

Note: Avoid the use of adapters and elbows

whenever possible.

Refer to figure 3 while following the instructions below.

1. Seat the bullet so that half of the thickness of

the insulator is nested in the counterbore of each

connector flange.

2. Place the load resistor so that it will be aligned

with the coaxial input line.

3. Push in on the center contact.

4. Tighten the flange nuts evenly all around (finger

tight).

5. Tighten the nuts evenly with wrenches.

8

Bird Model 8251D208

Termaline Coaxial Load Resistor

RF Coaxial Line

Bolt

Bullet

Flange

Figure 3

Connection to

Transmitting

Equipment

Advertising