Bird Technologies 8255 User Manual

Page 26

Advertising
background image

These tests are by no means a necessity to the operation

of the load but merely guidelines for the users informa-

tion and advisement.

Disassembly

There are no special techniques required for the repair or

replacement of components in these Termaline Load Re-

sistors.

Tools

Required

Models 8251 and 8255 - A screwdriver and a small

wrench are they only tools needed for these models.

Model 8252 - A screwdriver, a small wrench, and an ad-

justable wrench (for the connector bolts) will be needed.

RF Connector

This section applies to the Models 8251 and 8255. (The

Model 8252 has a 3-1/8 inch EIA flanged connector and

must be returned to the factory for connector replace-

ment). The connector on the Models 8251 and 8255 are

“Quick-Change” design that permits easy interchange

with the use of only a screwdriver. This process does not

interfere with the essential coaxial continuity of the load

resistor RF input or the coolant oil seal. For replacement,

proceed as follows:

1. Remove the four 8-32 x 5/16 screws from the cor-

ners of the RF connector flanges.

2. Pull the connector straight out of its socket.

Bird Model 8251/52/55 Termaline Coaxial Load Resistor

14

50.0

Figure 3

Measuring DC

Resistance