Temp, Id.01 - id.66, Curr – Blizzard Lighting V12 The Puck (REV A) User Manual

Page 14: Page 14, Ar2.s

Advertising
background image

Page 14

The Puck™ V12 Manual Rev. A

© 2013 Blizzard Lighting, LLC

6.)

AR2.S

- Architectural Mode #2 w/strobe (RGBAW, 7-Ch.)

Channel

Value

What It Does

1

000 <--> 255 Master Dimmer (0% <--> 100%)

2

000 <--> 255 Red Intensity (0% <--> 100%)

3

000 <--> 255 Green Intensity (0% <--> 100%)

4

000 <--> 255 Blue Intensity (0% <--> 100%)

5

000 <--> 255 Amber Intensity (0% <--> 100%)

6

000 <--> 255 White Intensity (0% <--> 100%)

7

000 <--> 255 Strobe

7.)

HSV

- Hue, Saturation, Value (3-Ch.)

Channel

Value

What It Does

1

000 <--> 255 Hue (0% <--> 100%)

2

000 <--> 255 Saturation (0% <--> 100%)

3

000 <--> 255 Brightness (0% <--> 100%)

ID

ID Address Selection

ID Address mode allows you to utilize multiple fixtures on only 1 DMX universe

while maintaining full individual control over each fixture. You can enable or

disable ID address operation within the

SET

menu. Control settings are found in

STAG

mode, channel 11.

(see stage mode table on page 12)

.

• Id.01 - Id.66

- Sets the ID# for the fixture.

TEMP

Temperature Functions

Allows the user to set a temperature protection cutoff (default is 85 degrees

Celsius), and displays the current fixture temperature.

• CURR

- Displays current temperature.

• TOP

- Sets the max temperature before shutoff (0-150, 85=default).