Operating – Dulce Systems Duo-FireWire User Manual

Page 11

Advertising
background image

Page 20

Duo-FireWire Installation and User’s Manual

6. Operating

6.1.

DISK Activity Indicators

The DISK 1 and DISK2 Indicators show the activities of the two disk drives in the

Duo-FireWire. When the indicator is on it shows the particular drive is active.

DISK 1 and DISK 2 indicators do not always come on at the same time.

Depending on the Operating Mode selected, these indicators will act differently.

See the particular selected mode for more specific details.

6.1.1. RAID 0 - Stripe Mode (Performance)

The DISK1 and DISK2 indicators will be mostly active at the

same time. In the RAID 0 scheme data is alternately stored

between the two drives at a rapid rate. For example, when a

file is written to the Duo-FireWire, a small portion will be stored

on DISK 1, the next small portion on DISK 2, the next small

portion back on DISK 1. This process is called data striping.

This scheme provides the highest data rate that is the sum of

the two individual disk drives.

6.1.2. RAID 1 - Mirror Mode (Protection)

RAID 1 - During read operation

During read operating, one of the DISK

indicators will come on, either DISK 1 or

DISK 2. Since data on both drives are

identical, the internal controller will pick the

most efficient disk to use.

RAID 1 - During write operation

During write operation, both DISK 1 and DISK 2’s indicators

will come on. In Mirror Mode, data sent to the Duo-FireWire

will be written to both disk drives for redundancy. If one of the

DISK indicators do not come on during write operations, that

disk has failed and the unit will need servicing. Normal

operating continues on the remaining surviving disk drive.

RAID 1 - During write operation (with a failed disk drive)

A failed disk is indicated by the

absence of disk activities during

write operations. Should a disk

become inoperative (defective), the DISK

indicator of that drive will never come on. In

such a case, the unit will need servicing.

X

X

Page 21

Duo-FireWire Installation and User’s Manual

RAID 1 - No operation (DISKs blinks)

If there are no read or write activities to the Duo-FireWire and

both DISK 1 and DISK 2 indicators are blinking, this indicates

the Duo-FireWire is performing a Syncing operation. This is

where the Duo-FireWire has detected a Mirror Mode out of

sync condition and is in the process of updating the portion of

the disk drive that is out of sync.

During the Syncing operation, data access to the unit will be slow. It is best to

allow the unit to be dedicated fulltime to complete the Syncing. This process can

take a few minutes to a few hours.

6.1.3. SPAN - Linking Mode (Simplicity)

DISK 1 indicator comes on when accessing

data on the 1

st

half of the Duo-FireWire

space. DISK 2 indicator will come on when

accessing on the 2

nd

half of the Duo-

FireWire space.

6.1.4. JBOD - Just a Bunch of Disks Mode (Individual)

DISK 1 indicator comes on when disk 1 is

being accessed. DISK 2 indicator comes on

when disk 2 is being accessed. Each of the

two disk drives in the Duo-FireWire shows

up as two independent disk drives.

Advertising