Bryant DURAPAC PLUS 581A User Manual

Page 43

Advertising
background image

—

43

—

_ _ .A

—

Circuit A

AHA

—

Adjustable Heat Anticipator

AL

—

Ambient Limit

AUX

—

Auxiliary Contact

_ _ .B

—

Circuit B

_ _ .C

—

Circuit C

C

—

Compressor, Contactor

CAP

—

Capacitor

CB

—

Circuit Breaker

CC

—

Compressor Contactor

CCH

—

Crankcase Heater

CLO

—

Compressor Lockout

COMP —

Compressor

CR

—

Compressor Relay

CS

—

Current Sensor

DU

—

Dummy Terminal

FCS

—

Fan Cycling Switch

FIOP

—

Factory-Installed Option

FPT

—

Female Pipe Thread

FS

—

Flame Sensor

FU

—

Fuse

GND

—

Ground

GV

—

Gas Valve

GVR

—

Gas Valve Relay

HACR —

Heating, Air Conditioning, and Refrigeration

HS

—

Heat Sensor

HERM —

Hermetic

HPS

—

High-Pressure Switch

I

—

Ignitor

IA

—

Indoor Air

IAQ

—

Indoor-Air Quality

IDM

—

Induced-Draft Motor

IFC

—

Indoor-Fan Contactor

IFCB

—

Indoor-Fan Circuit Breaker

IFM

—

Indoor-Fan Motor

IGC

—

Integrated Gas Controller

IRH

—

Indoor Relative Humidity

LAFC

—

Low Ambient Fan Control

LPS

— Low Pressure Switch

LS

— Limit Switch

MGV

— Main Gas Valve

OA

— Outdoor Air

OAS

— Outdoor Air Sensor

OAT

— Outdoor-Air Temperature

OFC

— Outdoor-Fan Contactor

OFM

— Outdoor-Fan Motor

ORH

— Outdoor Relative Humidity

PEC

— Power Exhaust Contactor

PEM

— Power Exhaust Motor

PL

— Plug

QC

— Quadruple Contactor

QT

— Quadruple Terminal

RAS

— Return Air Sensor

RAT

— Return Air Thermostat

RS

— Rollout Switch

SAT

— Supply-Air Temperature

TB

— Terminal Block

TC

— Thermostat Cooling

TH

— Thermostat Heating

TRAN — Transformer

Terminal (Marked)

Terminal (Unmarked)

Terminal Block
Splice

Splice (Marked)

Splice (Field Supplied)
Factory Wiring

Field Control Wiring

Field Power Wiring
Accessory or Optional Wiring

To Indicate Common Potential Only,
Not To Represent Wiring

NOTES:

1. Factory wiring is in accordance with the National Electrical Codes. Any field

modifications or additions must be in compliance with all applicable codes.

2. Use 75 C minimum wire for field power supply. Use copper wires for all units.
3. All circuit breakers “Must Trip Amps” are equal to or less than 156% RLA

(rated load amps).

4. Compressor and fan motors are thermally protected. Three-phase motors

protected against primary single phase conditions.

5. The CLO locks out the compressor to prevent short cycling on compressor

overload and safety devices; before replacing CLO, check these devices.

THERMOSTAT/IGC MARKINGS

BM —

Blower Motor

RS

—

Rollout Switch

C

—

Common

RT

—

Power Supply

CM —

Inducer Motor

SS

—

Speed Sensor

CS

—

Centrifugal Switch

W

—

Thermostat Heat

G

—

Fan

W1

—

1st Stage of Heating

GV —

Gas Valve

W2

—

2nd Stage of Heating

IFO —

Indoor Fan On

X

—

Alarm Output

LI

—

Line I

Y1

—

1st Stage of Cooling

R

—

Thermostat Power

Y2

—

2nd Stage of Cooling

LEGEND

Fig. 40 — Low Voltage Control Schematic

Fig. 41 — Power Schematic and Fig. 42 — Component Arrangement