Watts KA2-A User Manual

Watts intelliflow, Retrofi t kit ka2-a, Installation instructions

Advertising
background image

IS-KA2-A

If Your Current Installation Looks Like:

Final Installation Will Look Like:

This kit is used to replace the following Watts washing machine shutoff valves: the wall mounted
Watts Models #2 Duo-Cloz valve and the wall mounted IntelliFlow™ Models:

A2, A2C, A2C-M with the new Watts IntelliFlow Model A2C-M1.

Watts IntelliFlow

Retrofi t Kit KA2-A

Installation Instructions

Note: The union tailpieces supplied with the IntelliFlow are not
required when the adapters are used.

Installation

1. Shut off the water supply to the existing valve.
2. Disconnect the water supply connection from the valve to

the washing machine. Use masking tape to indicate the hot
and cold supply hoses.

A2, A2C or A2C-M Valves

A3. Unplug the unit from the wall. Unplug the washing ma-

chine from the A2.

A4. R e m o v e t h e c o v e r b y l o o s e n i n g t h e f o u r ( 4 )

1

4

"

hex head screws (A) using a

1

4

" open end wrench.

(See Figure 1)

A5. Remove the A2 by unscrewing both slotted screws (B) on

the top of the valve. Go to step #6.

#2 Valve

B3. Remove the #2 valve by unscrewing both slotted screws

(A) on the top of the valve. (See Figure 2)

B4. Remove the body of the valve by drawing the valve off the

inlet fi ttings (B). Go to step #6.

Wall box style with #2 Style, A2, A2C or A2C-M

A2C-M1

KA2-A

or

Figure 1

Figure 2

(A)

(A)

(A)

(B)

(B)

IS-KA2-A.indd 1

9/12/08 2:40:43 PM

Advertising