FH-1-MI-PEX

IS-FH-1-M1-PEX

NOTE: The frost-proof sill cock assures no-freeze operation
because the valve mechanism shuts off water inside the building
where it is heated. If building will be unheated for any length of
time, then all water lines should be drained and plumbing fi xtures
winterized.

Please provide this instruction sheet to the end user.

Installation Instructions

Series FH-1-M1-PEX

1

2

" PEX Inlet x

3

4

" Hose

Freezeless, Self Draining Wall Hydrants,
PEX End Connection

Ordering

Kit

Valve

Code

No.

No.

Series Size

0723126

FH-M1-RK FH-M1 All

Kit consists of: Check sub-assembly, Check spring and
Stem packing.

Series FH-1-M1, FH-2-M1, and FH-1-M1-PEX

To Service:

Close supply pressure to frost proof sill cock fl ange. Remove
handle and bonnet, slide stem out. Replace all rubber parts and
disc screw. Reinsert stem, bonnet and handle.

A plastic siding wedge is provided to compen-
sate for lap siding installations. Slip the wedge
between frost-proof fl ange and siding to form
an attractive fi nish and solid base for mounting.

Secure sill cock fl ange with two #8 or #10 oval-
head wood screws (of proper length) or with
appropriate masonry hardware.

SIDING
WEDGE

IS-FH-1-M1-PEX 0826

EDP#2915031

© Watts, 2008

USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com

Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

W a t e r S a f e t y & F l o w C o n t r o l P r o d u c t s

Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of
original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER
WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special
or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting
from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no
control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above
limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to
determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

INSTALLERS PLEASE NOTE:

A. Hose end must be installed suffi ciently lower than seat

end to allow for proper drainage.

B. Follow PEX tubing manufacturer's crimp joining

instructions. Watts PEX end freezeless wall hydrants
conform to ASTM F1807-04 PEX end specifi cations.

Crimp outside diameters should fall within these dimen-
sions when measured with a micrometer or caliper.

RING SIZE

MINIMUM

MAXIMUM

1

2

" 0.700" 0.715"

IS-FH-1-M1-PEX.indd 1

9/9/08 11:40:08 AM