Garden Sun Heater HPS-C-PC Tabletop Heater User Manual

Page 7

Advertising
background image

Gas Tank Assembly

Provided with a listed overfilling prevention device.

The cylinder used must include a collar to protect the cylinder valve.
Never connect an unregulated propane cylinder to the heater.

Turn off the control knob of the burner.Fix the 1.02 lb.
propane cylinder to the regulator(rotate the propane cylinder
clockwise toward the regulator connecting untill tighten it).

Provided with a cylinder connection device compatible with the
connection for the appliance.

A dented, rusted or damaged propane cylinder may be hazardous
and should be checked by your cylinder supplier. Never use a
propane cylinder with a damaged valve connection.

The propane cylinder must be constructed and marked in
accordance with the specifications for LP gas cylinders of the
U.S. Department of Transportation (DOT). or the Standard for
Cylinders, Spheres and Tubes for Transportation of Dangerous
Goods and Commission, CAN/CSA-B339.

You must provide propane gas and propane cylinder .
Use a standard 1.02 lb. propane cylinder only.

Storage of an appliance indoors is permissible only if the
cylinder is disconnected and removed from the appliance.
A cylinder must be stored outdoors in a well-ventilated area
out of the reach of children. A disconnected cylinder must
have dust caps tightly installed and must not be stored in a
building, garage or any other enclosed area.

Standard 1.02 lb. tank

orientation to provide
vapor withdrawal

6

Close the door plate and lock it with the handle.

The cylinder be disconnected when the appliance is not use.

Replacement pressure regulator must be that specified by the
appliance manufacturer.The pressure regulator and hose assembly
supplied with the appliance must be used.

Storage of an appliance indoors is permissible only if the cylinder
is disconnected and removed from the appliance.

An appliance may be installed with shelter no more inclusive than:
(a) With walls on all sides,but with no overhead cover.
(b) Within a partial enclosure which includes an overhead cover
and no more than two side walls. These side walls may be
parallet, as in a breezeway, or at right angles to each other.
(c) Within a partial enclosure which includes an overhead cover
and three side walls, as long as 30 percent or more of the
horizontal periphery of the enclosure is permanently open.

The pressure regulator supplied with the appliance must
be used.

Only a cylinder marked “propane” can be used.

Certain materials or items, when stored under the heater,
will be subjected to radiant heat and could be seriously
damaged.

The installation must conform with local codes, or in the
absence of local codes,with National Fuel Gas Code,
ANSI Z223.1/NFPA54, Natural Gas and Propane Installation
Code, CSA B149.1, or Propane Storage and Handling
Code, B149.2.

(a) Do not store a spare LP-gas cylinder under or near this appliance;
(b) Never fill the cylinder beyond 80 percent full;

STEP 7:
Rotate regulator toward
opening in housing.

Line up threads on gas
cylinder with those on
the regulator.

Insert and rotate cylinder
clockwise until tight.

STEP 8:
Close access panel.

Advertising