WSW26

(Function setting 4)

Selector

No.

Function

Setting and Specifications

1
2

Not used.

3

Dialing during document
reading into the temporary
memory in in-memory message
transmission

0: Disable 1: Enable

4
5

No. of CNG cycles to be
detected
(when the line is connected via
the external telephone except in
the external TAD mode or via
the built-in telephone)

No. 4

5

0

0

:

0.5

(A)

0

1

:

1

(B)

1

0

:

1.5

(C)

1

1

:

2

(D)

6
7

No. of CNG cycles to be
detected
(when the line is connected via
the external telephone in the
external TAD mode, via the
built-in telephone in the TAD
mode, or via the machine in the
automatic reception of the F/T
mode)

No. 6

7

0

0 : 0.5

(A)

0

1 : 1

(B)

1

0 : 1.5

(C)

1

1 : 2

(D)

8 Not

used.

Selector 3: Dialing during document reading into the temporary memory in in-memory message

transmission

If this selector is set to "0," the machine waits for document reading into the memory to complete
and then starts dialing. This enables the machine to list the total number of pages in the header of
the facsimile message.

Selectors 4 and 5: No. of CNG cycles to be detected (when the line is connected via the external

telephone except in the external TAD mode or via the built-in telephone)

The machine interprets a CNG as an effective signal if it detects the CNG by the number of cycles
specified by these selectors when the line is connected via the external telephone except in the
external TAD mode or via the built-in telephone.

Selectors 6 and 7: No. of CNG cycles to be detected (when the line is connected via the external

telephone in the external TAD mode, via the built-in telephone in the TAD mode, or
via the machine in the automatic reception of the F/T mode)

The machine interprets a CNG as an effective signal if it detects the CNG by the number of cycles
specified by these selectors when the line is connected via the external telephone in the external
TAD mode, via the built-in telephone in the TAD mode, or via the machine in the automatic
reception of the F/T mode.