A) Attach each TRANS-FLO circular connector tail to a locking lamps harness, 
or single head extension, making sure to rotate the locking ring until it 
“ clicks” into its locked position. Securely connect both ends to the harness 
on the lamp before turning on the power. 
 
B) With the ballast power switched off, attach the Power /Dim Cable to the 
“POWER IN” port of the first ballast in the series.
D) Connect the Primary Power Feed (black) 3-pin U ground Edison plug to a
120 Volt AC non-dimming circuit. You do NOT connect the Dimming 
Line ( D )to a dimmer circuit. 
F) Switching the ballast to “NON-DIM” will turn on the lamps.
8
 
 
 
 
 
X04-25 SINGLE Head Extension, 25ft 
X04-12 SINGLE Head Extension, 12 ft 
Black, 4-pin male to female. Connects Trans-Flo 
Ballast to Single Locking Harness. Maximum of 25ft 
from Ballast to lamp for full dimming range control. 
 
 
 
 
 
 
 
HAR-4801 4ft SINGLE Locking Harness 
HAR-3601 3ft SINGLE Locking Harness 
HAR-2401 2ft SINGLE Locking Harness 
HAR-1501 15” SINGLE Locking Harness 
 
 
 
 
 
 
 
PWC-C TRANS-FLO Jumper Coupler 
To combine jumpers if more than 10 ft are required 
between ballasts.