Usa & c – La Cornue Château Series - Gas & Electrical Requirements User Manual
Page 4
I
NSTALLATION
Electrical connection
Page
31
LA CORNUE
Installation Guide Centenaire
08NOTINSTAL100/USA-2
2. Now the terminal block is accessible
3. The appliance is shipped with a strain relief device to secure power cord. Insert the power cord
through the strain relief and tighten it.
4. Insert the strain relief device into the hole and push it to the left. Tight up the power cord and
strain relief device with the screw.
5. Install the power cord: attach the wires to the
terminal block as follows:
- neutral (white wire) to N,
- the L1 and L2 (red and black wire) to P1 and P2,
- the ground to T (yellow / green).
NOTE: Make sure the wires are completely inserted
into the terminals and secure connections are
made.
6. Re-install the protection plate for the range or the cover for the cooktop.
7. Make sure that everything is properly secured.
R
EMINDER
: connections to main power supply preferably suppose to be hardwired into the wall
Junction Box compare using the Plugs and Outlet.
Fix the cable well below the hot air outlets, at the rear of the oven, never in front of them.
USA & C
AN
AD
A
Ranges
Terminal
block
Cooktops