6 mounting the return springs, Mounting the return springs, Series ra – Richter RA Series Actuators User Manual

Page 9: Installation and operating manual

Advertising
background image

Installation and Operating Manual

Series RA

9590-050-de

Revision 01

TM 5515 MPE/Wm

Seite 9

Edition 07/2003

4.6 Mounting the return springs

Warning - Danger of injury !

Loosen the end caps only when the actuator is
isolated from the compressed air supply.

In order to achieve a symmetrical press-
ure distribution, it is necessary to insert
the springs as shown in the diagrams
below.

Remove the end cap on the actuator.

Set the desired number of return
springs in the round insets in the
piston. Take care here to arrange
an even distribution of the springs
to spread the pressure evenly.
See Table 1.

Table 1

No. springs

Piston

left side

Piston

right side

2

1

1

3

1

1+4

4

1+4 1+4

5

1+4 2+4+6

6

2+4+6 2+4+6

7

2+4+6 2+3+5+6

8

2+3+5+6 2+3+5+6

9

2+3+5+6 1+2+3+5+6

10 1+2+3+5+6

1+2+3+5+6

11 1+2+3+5+6 all

12 all all

Replace the end cap onto the actua-
tor and screw in position, taking care
to observe the prescribed torque for
the screws, see Section 1.2.
Take care to observe the correct
position (marker UP on the cap) and
the state of the cap gasket ring.

Spring chamber

Advertising