If Sample Rate is displayed instead of time code frame rate, hold the Meters button and slide the RTN
switch left to view time code frame rate.

Time code modes

The time code mode determines if the 664 generates or reads time code and when

time code runs and stops. Time code mode is changed from the Setup Menu option

TIMECODE/SYNC > Time code Mode.

Rec Run (Record Run)

Generator mode. The 664 sends running time code while recording and stationary time code while

not recording. Time code in this mode defaults to the last stationary value at power-up. When

switching to Record Run from another mode, the internal generator will stop at the last number gen-

erated. A user-defined value can be jammed into the internal generator from the Setup Menu option

TIMECODE/SYNC > Set Generator TC.

Free Run

Generator mode. Time code runs continuously. The value can be set by “jamming value” in the Setup

Menu option TIMECODE/SYNC > Jam Menu or by manually setting a value from the Setup Menu

option TIMECODE/SYNC > Set Generator TC.

Free Run Auto Mute

Functions the same as Free Run mode except timecode signal is muted from the LEMO output when

the 664 is in stopped mode. This allows rec-run functionality when Rec Run mode is not suitable

(e.g. Multi-camera shoots). Note that timecode signal is still output during play and play-pause

modes.

24h Run (24 hour Run)

Generator mode. Time code runs continuously. When this Time Code Mode is selected or when

the time/date is altered, the time code value is jammed to the value of the time-of-day clock. The

value can be set by “jamming value” in the Setup Menu option TIMECODE/SYNC > Jam Menu or by

manually setting a value from the Setup Menu option TIMECODE/SYNC > Set Generator TC.

24h Run Auto Mute

Functions the same as 24h Run mode except timecode signal is muted from the LEMO output when

the 664 is in stopped mode. This allows rec-run functionality when Rec Run mode is not suitable

(e.g. Multi-camera shoots). Note that timecode signal is still output during play and play-pause

modes.

Ext-TC (External Time Code)

Reader mode. The internal time code generator follows an external time code signal appearing at the

time code input. If the external time code is removed the internal generator stops as well. Recording

is triggered manually with the Transport Control.

Ext-TC Auto-Rec (External Time Code Auto-Record)

Reader mode. The internal time code generator follows an external time code signal appearing at the

time code input. If the external time code is removed the internal generator stops as well. The 664 au-

tomatically begins recording when running time code is sensed. When stopped time code is sensed,

recording stops.

664 User Guide and Technical Information

31

Digital A

udio R

ecor

der

Advertising