PC7 CONTROLLER OPERATION / MAINTENANCE MANUAL

PAGE 15

5

TROUBLESHOOTING

Controller Will Not Operate or Cycles Erratically

Cause:

Solution:

• PC7 cap seal failure

• Remove caps from PC7 and replace PTFE cap seal.

• Debris in shuttle valve

• Isopropyl alcohol clean the shuttle sleeve and spool assy.

• Insuffisant air pressure

• Increase regulated supply pressure or check control

valves for proper operation.

Rotate PC7 speed control screw CW until it stops. Then
readjust for correct speed.

• Adjustment Screw Seal failure

• Replace adjustment screw assy.

• Spring bar failure

• Spring bar needs replacement if not flat.