04 power supply options and accessories, 04 power supply options and accessories -3 – Tweco 150XL CE PAK Master Without Latch Circuit User Manual

Page 15

Advertising
background image

Manual 0-2727

2-3

INTRODUCTION & DESCRIPTION

B. Gas Regulator/Filter Assembly

Specifications

The following specifications apply to the Gas Regulator/
Filter Assembly only:

1. Gas Regulator Maximum Gauge Pressure

Plasma: 160 psi (11.3 bar)

Secondary: 160 psi (11.3 bar)

2. Maximum Input Gas Pressure

125 psi (8.6 bar)

3. Filter

Coalescent type filter

C. Gas Requirements

1. Plasma

Gases: Compressed Air, Nitrogen, Argon/Hydrogen

Operating Pressure: 65 psi (4.5 bar)

Cold Flow:

Cutting: 50 - 78 scfh (23.6 - 36.8 lpm)

Gouging: 85 - 95 scfh (40.1 - 44.8 lpm)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 bar).

2. Secondary

Gases: Compressed Air, Carbon Dioxide (C0

2

), Ni-

trogen

Operating Pressure: 60 psi (4.1 bar)

Cold Flow:

Cutting: 340 scfh (160.4 lpm)

Gouging: 235 scfh (110.9 lpm)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 bar).

2.04 Power Supply Options and

Accessories

NOTE

Refer to Section 6, Parts Lists, for part numbers
and ordering information.

The following are accessories that are available for the
Power Supply:

A. High Pressure Regulators

High pressure regulators are available for air, nitro-
gen, and argon-hydrogen. The regulators are used to
set the proper pressure for the type of gas being used.

B. CNC Interface Cable

NOTE

Accessory is for use with Shielded PCM Torch &
Leads.

The CNC Interface Cable is available in two lengths:
25 ft (7.6 m) and 50 ft (15.2 m). The cable is used to
interface the Power Supply with an auxiliary control
device to provide OK-To-Move and ON/OFF signals.

C. Work Cable Kit

Power Supply is supplied with attached 20 ft (6.1 m)
work cable and clamp. Longer cables are available as
a user installed kit.

D. Remote Pendant Control

NOTE

Accessory is for use with Unshielded PCM Torch
& Leads.

Control used to manually start and stop cutting op-
erations from a location up to 25 ft. (7.6 m) from the
Plasma Power Supply.

Advertising