Manual 0-2727

4-3

OPERATION

2.

Plasma Gas Pressure Regulator/Filter Assembly

Pressure Regulator to adjust the plasma input gas
pressure to the Power Supply. The Pressure Regu-
lator has a built-in air line filter.

A-02297

5

2

3

4

1

6

Figure 4-4 Rear Panel

3.

Secondary Gas Pressure Regulator/Filter Assem-
bly

Pressure Regulator to adjust the secondary input
gas pressure to the Power Supply. The Pressure
Regulator has a built-in air line filter.

4.

Coolant Reservoir

The coolant reservoir supplies the system with
coolant to cool the torch and torch parts during
operation. The maximum capacity of the reser-
voir is two gallons of coolant.

Inside the reservoir, in the filler hole, is a basket
and deionizer bag. The bag removes charged par-
ticles from the coolant after it is returned to the
reservoir and prevents the coolant from becom-
ing conductive. If the coolant becomes conduc-
tive it must be replaced (see NOTE).

NOTE

Refer to Section 5.02, General Maintenance, sub-
sections 'E' and 'F' for procedures on checking and
replacing coolant.

5.

Gas Input

Input connections for plasma and secondary gases.
Acceptable gases are as follows:

Plasma Gases - Air, Nitrogen, Argon Hydrogen

Secondary Gases - Air, Nitrogen, Carbon Dioxide

WARNING

This unit not to be used with oxygen (O

2

).

6.

Two Stage Air Line Filter

Two Stage Air Line Filter Assembly will remove
moisture and contaminants from the air stream
when using compressed air. The filter is capable
of filtering to at least 5 microns.

4.03 Sequence of Operation

The following is a typical sequence of operation for this
cutting system. Refer to Appendix 2 for a block diagram.

1.

Close main power source disconnect.

a. AC power is available at the Power Supply.

2.

Place RUN/SET switch to RUN mode.

3.

Place the ON/OFF power switch on the front panel
of the Power Supply to ON.

a. Fan turns ON.

b. Coolant Pump turns ON.

c. AC Power indicator LED blinks ON and OFF

for eight seconds then stays ON.

d. Start-up pre-purge of gas.

4.

Place RUN/SET switch to SET mode.

a. Gas Solenoid opens and gas flows to set pres-

sure.

b. GAS indicator turns ON.

NOTE

GAS indicator will not come ON if the gas pres-
sure is set below 40 psi (2.8 bar) at the Regulator/
Filter Assembly or if coolant flow switch is not sat-
isfied.

5.

Place RUN/SET switch to RUN mode.

a. Gas flow stops.

b. GAS indicator turns OFF.