5

I.

Gas cycles on and off when power is turned on; AC indicator

flashes

1. Shield cup is loose.

a. Tighten shield cup by hand. Do not overtighten.

2. Torch tip, electrode, or start cartridge missing

a. Turn off power supply. Remove shield cup, install missing parts.

3. Start cartridge is stuck

a. Turn off power supply. Remove shield cup, tip, and start cartridge. Check lower end fitting on start cartridge

for free movement. Replace cartridge if lower end fitting does not move freely.

Art # A-07168

Spring-Loaded Cylinder
at Full Compression

Spring-Loaded Cylinder
at Full Extension

1/8” (3 mm)

5.06 Pilot Arc Problems

WARNING

The following tests must be performed with the power supply connected to primary input power. There are extremely
dangerous voltage and power levels present inside this unit. Do not attempt to diagnose or repair without proper
training in power electronics measurement and troubleshooting techniques.

Locate your symptom below:

A. Torch will not pilot; gas flows; AC indicator

ON, GAS

, TEMP , and DC

indicators OFF

1. Gas pressure is below power supply minimum requirement. (Minimum pressure for power supply operation is lower

than minimum required for torch operation.)

a. Adjust gas pressure per pressure setting label on power supply.