Tweco 151 with SL100SV User Manual

Page 90

Advertising
background image

SERVICE

5-22

Manual 0-4691

5

E. Gas flows; AC indicator

and GAS

indicators ON; TEMP indicator off; ON; DC

indicator

off or blinks on/off once.

1. Faulty IGBT or Output Diode Module Assembly(s)

a. Check per Subsection 5.08-C; repair as needed.

2. Faulty Main PCB

a. Test; repair as needed.

F. Gas flows; No arc in torch; AC

, GAS

, and DC

indicators ON; TEMP indicator

off

1. Faulty IGBT(s)

a. Measure between the following points on the IGBTs:

• IGBT A:

E4 to E10

E10 to E20

• IGBT B:

E23 to E27

E27 to E30

Voltage should be approximately 20 vdc before the start signal is active. If voltage measures greater than 100
vdc when the start signal is active, replace the respective IGBT(s).

E2

E3

E1

Secondary
Transformer

#32

#27

Input Diode
(mounts to
center chassis)

E1

E3

E2

Fuse

LT1

E33

J25

E10

E20

E7

E15

E30

E27

E32

J26

E23

J23

J24

J34

J33

J32

J18

J29

J27

J43

E5

E6

E4

E12

E17

J30

J31

E22

Art # A-04640

IGBT

PCB

E12

E17

TP4

TP1

J15

J11

J17

J16

U1

IGBT

PCB

IGBT

Module

IGBT

Module

Logic Board

Not Shown

Main PC Board Layout

Advertising