03 input wiring specifications, 03 input wiring specifications -2 – Tweco 51 CutMaster User Manual

Page 14

Advertising
background image

INTRODUCTION

2-2

Manual 0-2971

Power Supply Dimensions & Weight

Ventilation Clearance Requirements

22.5"

0.57 m

58 lb / 26 kg

10.75"

273 mm

16.375"

416 mm

Art # A-04612

Art # A-03379

6"

150 mm

24"

0.6 m

6"

150 mm

6"

150 mm

2.03 Input Wiring Specifications

Voltage

Freq.

1-Ph

3-Ph

1-Ph

3-Ph

(Volts)

(Hz.)

(kVA)

(kVA)

(Amps) (Amps)

1-Ph

3-Ph

1-Ph

3-Ph

1-Ph

3-Ph

208

60

9

42

60

10

10

230

60

9

37

60

10

10

400

50

8

11

15

12

12

400

60

8.5

12

15

12

12

460

60

14

17.5

25

12

12

460

60

8

10

15

12

12

Fuse (Amps)

Wire (AWG)

Wire (Canada)

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electric Code

CutMaster 51 Power Supply Input Wiring Requirements

Input

Power Input

Current Input

Suggested Sizes (See Notes)

NOTES

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.

Cable conductor temperature used is 167° F (75° C).

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS / LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER

use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.

Advertising