INSTALLATION

3-4

Manual 0-2971

3.04 Gas Connections

A. Connecting Gas Supply to Unit

The connection is the same for compressed air or high pressure cylinders. Refer to subsection 3.4-B or 3.4-C if an
optional air line filter is to be installed.

1. Connect the air line to the inlet port. The illustration shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do not use
Teflon tape as a thread sealer, as small particles of the tape may break off and block the small air passages in the torch.

Art # A-02999

Hose Clamp

1/4 NPT to 1/4"

(6mm) Fitting

Regulator/Filter
Assembly

Inlet Port

Gas Supply
Hose

Bowl

Air Connection to Inlet Port