Cutmaster a40 – Tweco A40 CutMaster User Manual

Page 19

Advertising
background image

CUTMASTER A40

Manual 0-4978

INTRODUCTION

2-3

2.05 INPUT WIRING SPECIFICATIONS

CutMaster A40 Power Supply Input Cable Wiring Requirements

Input voltage

Freq

Power Input

Suggested Sizes

Volts

Hz

kVA

I max

I1eff

Fuse (amps)

Flexible Cord

(Min. AWG)

1 Phase

208

60

10.4

47

30

50

10

230

60

10.8

45

29

50

10

460

60

15.2

31

20

35

12

3 Phase

208

60

5.4

26

17

30

12

230

50/60

5.8

24

16

30

12

380

50/60

6.1

16

11

20

14

400

50/60

6.4

16

11

20

14

460

60

7.4

16

10

20

12

600

60

7.8

13

11

15

12

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electric Code

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations

refer to local or national codes.

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be used

to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER use replaceable element fuses like UL Class H, or “one-time” fuses like UL Class K5.