Optional Single-Stage Filter Element Replacement

These instructions apply to power supplies where the optional

Single-Stage Filter has been installed.

The Power Supply shuts down automatically when the Filter

Element becomes completely saturated. The Filter Element

can be removed from its housing, dried, and reused. Allow

24 hours for Element to dry. Refer to Section 6, Parts List, for

replacement filter element catalog number.

1. Remove power from power supply.

2. Shut OFF air supply and bleed down system before

disassembling Filter to change Filter Element.

3. Disconnect gas supply hose.

4. Turn the Filter Housing Cover counter-clockwise and

remove it. The Filter Element is located inside the

housing.

Art # A-02476

Filter

Element

(Cat. No. 9-7741)

Housing

Cover

Barbed

Fitting

Spring

Assembled Filter

O-ring

(Cat. No. 9-7743)

Optional Single-Stage Filter Element Replacement

5. Remove the Filter Element from the housing and set

Element aside to dry.

6. Wipe inside of housing clean, then insert the replace-

ment Filter Element open side first.

7. Replace housing on Cover.

8. Reattach gas supply.

NOTE

If unit leaks between housing and cover, inspect

the O-Ring for cuts or other damage.

Optional Two-Stage Filter Element Replacement

The Two-Stage Air Filter has two Filter Elements. When the Filter

Elements become dirty the Power Supply will continue to oper-

ate but cut quality may become unacceptable. Refer to Section

6, Parts List, for replacement filter element catalog number.

1. Shut OFF primary input power.

2. Shut OFF air supply and bleed down system.

WARNING

Always turn OFF the air supply and bleed the system

before disassembling the Filter Assembly as injury

could result.

3. Loosen the two bolts on the top of the Filter Assembly

enough to allow the Filter Elements to move freely.

4. Note the location and orientation of the old Filter Ele-

ments.

5. Slide out the old Filter Elements.

First & Second

Stage

Cartridges

(as marked)

Art # A-02942

Optional Two-Stage Filter Replacement

6. Slide the replacement Filter Elements into the Filter

Assembly, with the same orientation as noted in Step

4 above.

7. Hand tighten the two bolts evenly, then torque each

bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Improper torque

may damage the gasket.

8. Slowly apply air pressure to the assembly, checking

for leaks.

NOTE

A small amount of air leakage from the bottom

fitting is normal.

This completes the parts replacement procedures.