02 preparations for operating, Cutskill 35a – Tweco 35A CutSkill Power Supply and SL40 Torch EU version User Manual

Page 22

Advertising
background image

cutskill 35A

OPERATION 4-2 Manual 0-5180

8. Parts - in - place ( PIP)

This unit is fitted with a protective interlock mode (parts in place sensor), which serves to protect the user from

potentially dangerous voltages when changing consumables. If the shield cup is not correctly fitted, the output

will be disabled and the air indicator will flash.

NOTE

All consumables must be correctly fitted and maintained to ensure correct operation.

4.02 Preparations For Operating

At the start of each operating session:

!

WARNING

Disconnect primary power at the source before assembling or disassembling power supply, torch parts,

or torch and leads assemblies.

A. Torch Parts Selection

Check the torch for proper assembly and appropriate torch parts. The torch parts must correspond with the type

of operation, and with the amperage output of this power supply (35 amps maximum). Use only genuine Thermal

Dynamics parts with this torch.

Art # A-09793_AC

Start Cartridge,
Cat. No. 9-0097

Electrode, Cat. No. 9-0096

Shield Cup, Cat. No. 9-8218

Worn Electrode

Worn Tip

35 Amp Drag Tip, Cat. No. 9-0091

Shield Cup, Cat. No. 9-0098

Advertising