2.01 Scope of Manual

This manual contains descriptions, operating instructions
and maintenance procedures for the Liquid Cooled Maxi-
mizer 300 Torch and Torch Leads Assemblies. Service of
this equipment is restricted to properly trained person-
nel; unqualified personnel are strictly cautioned against
attempting repairs or adjustments not covered in this
manual, at the risk of voiding the Warranty.

Read this manual thoroughly. A complete understand-
ing of the characteristics and capabilities of this equip-
ment will assure the dependable operation for which it
was designed.

2.02 General Description

NOTE

Refer to Section 2.05, Introduction To Plasma, for
a more detailed description on plasma theory.

The Liquid Cooled Maximizer 300 Torch is a liquid cooled
torch that provides cutting capacity of up to 2 inches (50.8
mm), or 3/4 inches (19 mm) for production speed cut-
ting, at 150 amperes. In the torch, two torch leads pro-
vide plasma and secondary gas to the torch head. The
leads also provide the closed loop for the liquid coolant
flow from the Power Supply.

Plasma torches are similar in design to the common au-
tomotive spark plug. They consist of negative and posi-
tive sections which are separated by a center insulator.
Inside the torch, the pilot arc is initiated in the gap be-
tween the negatively charged electrode and the positively
charged tip. Once the pilot arc has ionized the plasma
gas, the superheated column of gas flows through the
small orifice in the torch tip, which is focused on the metal
to be cut. The torch connects to a tool-free quick-connect
receptacle on the Arc Starter Box.

2.03 Specifications & Design

Features

A. Maximizer 300 Torch

The following applies to the Liquid Cooled Maximizer
300 Torch only:

1. Maximizer 300 Torch Configuration & Dimensions

Maximizer 300 Machine Torch is supplied with a
Metal Rack and Pinion Mounting Assembly. An op-
tional Phenolic Pinch Block Mounting Assembly is
available.

Min. 6.750 in (171.5 mm)

Max. 11.125 in (282.6 mm)

1.937 in

(49.2 mm)

1.38 in

(35 mm)

17.350 in

(441 mm)

1.875 in

(47.6 mm)

1.531 in

(38.9 mm)

0.718 in

(18.2 mm)

A-01023

Figure 2-1 Maximizer 300 Machine Torch

2. Torch Leads Length

25 ft (7.6 m)

50 ft (15.2 m)

Extendable up to 100 ft (30.5 m) from the Power Sup-
ply

3. Torch Ratings

Ambient

Temperature

104° F

(40° C)

Duty Cycle

100% @ 150 Amps @ 0.5 gpm

(1.89 lpm) Coolant Flow Rate

Maximum Current

300 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

12 kV

Torch Ratings