Appendix 3: gas flow comparison chart – Tweco 300 Maximizer User Manual

Page 68

Advertising
background image

APPENDIX

A-24

Manual 0-2554

APPENDIX 3: GAS FLOW COMPARISON CHART

Material

Plasma

Secondary Amperage

SCFH

lpm

SCFH

lpm

Notes

Aluminum

Air

Air

50

63

30

190

90

100

83

39

125

59

150

83

39

125

59

ArH2

N2

150

80

38

130

61

N2

H2O

100

83

39

8

8

Sec gph

150

83

39

9

9

Sec gph

Mild Steel

Air

Air

50

63

30

85

40

100

83

39

140

66

150

83

39

140

66

Air *

Air

100

83

39

300

142

150

83

39

300

142

O2

Air

50

60

28

95

45

100

83

39

140

66

150

83

39

140

66

O2 *

Air

100

83

39

300

142

150

83

39

300

142

Stainless Steel

Air

Air

50

78

37

230

108

100

83

39

140

66

150

83

39

140

66

Air *

Air

100

83

39

300

142

150

83

39

300

142

ArH2

N2

150

83

39

180

85

N2

H2O

100

83

39

8

8

Sec gph

150

83

39

3 to 9

3 to 9

Sec gph

* = Cutting is done wet or underwater (water table)

Plasma

Secondary

Gas Flow Comparison Chart

Flow Used

Gases Used

Advertising