Tweco Max 300 w-Merlin 6000GST User Manual

Page 38

Advertising
background image

SERVICE

5-8

Manual 0-2642

3. Visually check that the control wires, pilot lead

connection, and negative lead connections are
properly connected and in good condition (no
shorts or arcing).

• If problems are evident, repair or replace as

required.

• If there are no visual problems, then proceed

to Step 4.

4. Check the pilot lead, negative lead and control

wires for opens from one end of the torch leads to
the other.

• If open, replace leads or open component

of the Torch Leads Assembly.

• If not open, then proceed to Step 5.

5. Check the pilot and control wires for shorts to

other components in the Torch Leads.

• If shorted, then replace Torch Leads.

• If not shorted, then proceed to Step 6.

6. Carefully reassemble the components and recheck

the completed assembly per paragraph ‘B’, Step
3 to confirm that the components have been prop-
erly assembled.

This completes the checks for the proper operation of the
Torch Head and Torch Leads.