Figure 3-5 internal packing material, Figure 3-7 rear panel connections, Figure 3-8 input terminal board – Tweco PAK 44G User Manual

Page 20: Paper band, Input ac cable strain relief, Input ac terminal board

Advertising
background image

INSTALLATION PROCEDURES

14

Manual 0-2686

This unit connected for ______ volts

Refer to Instruction manual for other voltage conncts.

Discard this label

after connecting input lines.

Paper Band

A-01884

Figure 3-5 Internal Packing Material

2. Check for possible loose connections and damage that

may have occurred during shipment.

CAUTION

Input voltage of the available three phase power
source must correspond to the operating voltage of
the Pak 44G.

Power Transformer

Terminal Board

Internal

Power Leads

Power Transformer

(T1)

A-01885

Figure 3-6 Main Terminal Board and Power

Transformer Connections (208/230/460 Volt

Transformer Shown)

3. The leads are fed through the “INPUT” fitting in the

back of the unit.

PLASMA

GAS

SECONDARY

GAS WATER SHIELD

INPUT

FAN

ROTATION

4FU

15A

5FU

15A

6FU

15A

HI - FLOW WATER SHIELD

ON

OFF

Input AC Cable

Strain Relief

A-02099

Figure 3-7 Rear Panel Connections

4. With the primary power disconnect switch open, con-

nect the electrical ground and primary power leads
to the terminals on the upper right hand side (facing
the unit from the front.) Recommended wire sizes
are shown in Appendix I.

Input AC

Terminal Board

A-01886

Figure 3-8 Input Terminal Board

5. The leads are attached to terminals L1, L2, L3.

6. A proper ground connection must be made to the brass