SECTION 3: INSTALLATION PROCEDURES

Move the power selection plug to the desired input con-
nection for 208/230/240V, 380/415V, or 460V operation
per the label attached to the panel.

Voltage Selection

Connector

380/415 Volts

460 Volts

208/230/240 Volts

A-00911

Voltage Selection

Label

Figure 3-2 Input Voltage Selection

3.07 Primary Input Power Cable

Connections

Units ordered as 230V, single-phase, will have a six foot
power input cable and plug factory installed. For all other
units, a cable must be provided by end user. Recom-
mended cable sizes are specified in Appendix I.

1. Route the primary power cable through the strain re-

lief fitting in the rear panel of the Power Supply and
tighten strain relief screws.

AC Input Power

Cable Strain Relief

AC Input

Power Cable

A-00912

Figure 3-3 AC Input Power Cable Strain Relief

2. Connect the input cable inside the Power Supply for

the type of operation per the following:

Three-Phase Operation

Three-phase operation requires a 3-conductor cable
with ground.

a. Locate the ground stud and remove the top nut

and washer.

b. Install a lug terminal on the ground wire.

c. Place the ground wire onto the ground stud

and secure with the nut and washer.

d. Insert the other three wires into the L1, L2, and

L3 terminals on the contactor.

e. Tighten all set screws.

AC Input

Power Cable

L1

L2

L3

GND

Input Contactor

A-01329

Figure 3-4 Primary Power Cable Connections -

Three-Phase Operation

Single-Phase Operation

Single-phase operation requires a 2-conductor cable
with ground.

Advertising