Appendix i: input wiring requirements – Tweco PakMaster 50XL Plus User Manual
Page 39

Manual 0-2744
33
APPENDIX
APPENDIX I: INPUT WIRING REQUIREMENTS
In p u t
P o w er In p u t
C u r r en t In p u t
S u g g e st ed S iz es ( S ee N o te s)
V o lta g e
F r e q .
1- P h
3- P h
1- P h
3- P h
F u se ( A m p s)
W ir e (A W G )
W ir e (C an ad a)
( V o lt s)
( H z )
( kV A )
( kV A ) ( A m p s ) ( A m p s )
1- P h
3- P h
1- P h
3- P h
1- P h
3- P h
208
50/60
8.2
7.2
39.6
20
45
25
8
10
8
10
230
50/60
8.2
7.2
35.6
18
45
25
8
10
8
10
240
50/60
8.3
7.3
34.4
17.5
45
25
8
10
8
10
380
50/60
9.9
8.6
26
13
30
20
10
14
10
14
415
50/60
9.9
8.6
23.8
12
30
20
10
14
10
14
460
50/60
9.9
8.8
21.5
11
25
20
10
14
10
14
575
R equi r es T ra ns for m er M od ul e
Li n e V o l tages w i th S u gges ted C i r c ui t P r otec ti on an d W i re S i z es
B as ed on N ati ona l E l ec tr i c C ode and C ana di an E l ec tri c al C ode
NOTES
The table above is based on the following output current and voltage: 125VDC @ 40A
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER
use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.
Flexible cable must have an outside diameter of 0.69 inches (17.5 mm) or greater.