Tweco PCM-120 Machine Torch User Manual

Page 14

Advertising
background image

INTRODUCTION & DESCRIPTION

2-2

Manual 0-2698

B. Torch Leads Lengths

25 ft (7.6 m) or 50 ft (15.2 m)

C. Cutting Range

Most materials up to 1- 1/2 inch (38.1 mm)

D. Pierce Rating

3/4 inch (19.05 mm)

E. Transfer Distance

3/8 inch (9.5 mm)

F. Torch Ratings

Ambient

Temperature

104° F

(40° C)

Duty Cycle

100% @ 120 Amps @ 0.6 gpm

(2.3 lpm) Coolant Flow Rate

Maximum Current

120 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

12 kV

Torch Ratings

G. Torch Parts

Gas Distributor, Electrode, Tip, Shield Cup

Water Tube Extension for Gouging Only

H. Gas Supply Requirements

1. Plasma

Gases: Compressed Air, Nitrogen (N2), Argon/
Hydrogen only

Pressure: 65 psi (4.5 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.62 bar)

Cold Flow:

Cutting: 50-78 scfh (23.6-36.8 lpm)

Gouging: 85-95 scfh (40.1-44.8 lpm)

scfh = standard cubic feet per hour

NOTE

Cold flow is measured before the main arc is activated.
When pressure is set correctly, the plasma gas flow rate
is significantly lower when the arc is initiated.

2. Secondary

Gases: Compressed Air, Carbon Dioxide (CO2),
Nitrogen (N2) only

Pressure: 60 psi (4.1 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.62 bar)

Cold Flow:

Cutting: 340 scfh (160.4 lpm)

Gouging: 235 scfh (110.9 lpm)

scfh = standard cubic feet per hour

I.

Plasma Power Supply Used With

• PakMaster 150XL

J. Weight

• Hand Torch

25 ft (7.6 m) Leads - 11.4 lbs (5.17 kg)

50 ft (15.2 m) Leads - 20.4 lbs (9.25 kg)

• Machine Torch

25 ft (7.6 m) Leads - 12.8 lbs (5.81 kg)

50 ft (15.2 m) Leads - 20.8 lbs (9.43 kg)