CUSTOMER/OPERATOR SERVICE

5-10

Manual 0-2698

3. Visually check that the torch switch wires, pilot

lead connection, and negative lead connections
are properly connected and in good condition (no
shorts or arcing).

• If problems are evident, repair or replace as

required.

• If there are no visual problems, then proceed

to Step 4.

4. Check the pilot lead, negative lead and switch con-

trol wires for opens from one end of the torch leads
to the other.

• If open, replace leads or open component of

the Torch Leads Assembly.

• If not open, then proceed to Step 5.

5. Check the pilot and switch control wires for shorts

to other components in the Torch Leads.

• If shorted, then replace Torch Leads.

• If not shorted, then proceed to Step 6.

6. Carefully reassemble the components and recheck

the completed assembly per paragraph ‘B’, Step
3 to confirm that the components have been prop-
erly assembled.

This completes the checks for the proper operation of the
Torch Head and Torch Leads.