09 external cable connections – Tweco RC6010 User Manual

Page 22

Advertising
background image

INSTALLATION PROCEDURES

18

Manual 0-2478

A-00720

OK-To-Move

Contact Closure

(NC)

J6-13 or

J29-12

System #1

Remote Control

External AC or DC Voltage

Maximum 115 Volts

Cutting Equipment

Controls

J6-16 or

J29-14

Figure 3-16 Wiring For One System Using External

Voltage

For systems using two or more plasma power supplies
connect the OK-To-Move contacts in series. Both con-
tacts need to be closed, normal condition, to have a com-
pleted circuit. When one plasma supply is not being used,
either by the plasma power supply power, STATION
SELECT, or ENABLE are turned OFF, the contact closure
for that system will be normally closed (NC). The sys-
tem that is turned ON controls the OK-To-Move signal to
the cutting equipment. Connect the external voltage be-
tween one side of each contact closure.

A-00721

OK-To-Move

Contact Closure

(NC)

J6-13 or

J29-12

System #1

Remote Control

OK-To-Move

Contact Closure

(NC)

System #2

Remote Control

Cutting Equipment

Controls

J6-16 or

J29-14

J6-16 or

J29-14

J6-13 or

J29-12

External AC or

DC Voltage

Maximum 115 Volts

Figure 3-17 Wiring For Two Or More Systems

Using External Voltage

3.09 External Cable Connections

A-00680

CNC

J29

PS

J37

CNC Control

Cable

Power Supply

Cable

Strain Relief

Figure 3-18 Cable Connections

1. Power Supply Cable

Connect the Control Cable to the rear panel of the
Remote Control to the receptacle marked J37 (PS).
Connect the other end of the cable to the rear panel of
the Power Supply for the following systems:

• TD-750 System

Connect cable to the Power Base Unit at recep-
tacle marked J27 (TO REMOTE CONTROL).

• Merlin 3000 and 6000 Systems

Connect cable to the Power Supply at receptacle
marked J15.

2. CNC Control Cable Using AMP Connector

NOTE

The supplied CNC cable is a shielded cable. Any
user supplied cable should also be of a shielded type.
The shields must be grounded only at the control-
ler or cutting machine ground.

1. Connect the CNC Control Cable to the rear panel

of the Remote Control to the AMP receptacle
marked J29 (CNC).

2. Connect the other end of the cable to the CNC Con-

trol Assembly per the following chart (refer to Ap-