07 declaration of conformity, 01 scope of manual, 02 general description – Tweco SC10 User Manual

Page 15: 03 specifications & design features

Advertising
background image

Manual 0-2479

2-1

INTRODUCTION & DESCRIPTION

SECTION 2:

INTRODUCTION &

DESCRIPTION

2.01 Scope of Manual

This manual contains descriptions, operating instructions
and maintenance procedures for the SC10 Standoff Con-
trol Accessory. Service of this equipment is restricted to
properly trained personnel; unqualified personnel are
strictly cautioned against attempting repairs or adjust-
ments not covered in this manual, at the risk of voiding
the Warranty.

Read this manual thoroughly. A complete understand-
ing of the characteristics and capabilities of this equip-
ment will assure the dependable operation for which it
was designed.

2.02 General Description

The SC10 Standoff Control Accessory extends the neces-
sary system controls away from the power supply and is
an accessory for use with standard machine torch sys-
tems.

The SC10 Standoff Control is designed to be used with
the RC6010 Remote Control. The Standoff Control is me-
chanically mated with the Remote Control, either top or
bottom, and electrically connects to the Remote Control
through a 34 circuit ribbon cable from which it receives
bias power (+48 vdc), torch voltage signal (0-12 vdc = 0-
200 arc volts) and sends and receives power supply and
CNC control signals such as start, arc transfer (OK-To-
Move) and standoff inhibit (CSD).

The Standoff Control operates the torch lifter motor as-
sembly to find height, regulate height and retract at end
of cut. Height is regulated by comparing the torch arc
voltage with a preset reference voltage (ARC VOLTS con-
trol) and using the resulting error voltage to raise and
lower the torch lifter motor.

A-00686

PLA

SM

A O

N

ARC VOLTS

RE

MO

TE

ST

AN

DO

FF

CO

NT

RO

L

T.H

.C. A

CTIV

E

PIER

CE

HT (i

nche

s)

0.1

0.3

0.4

0.5

0.2

END

OF C

UT

RET

RAC

T (%

)

0

25

75

100

UP

DN

TOR

CH

TORCH

MO

DE

MODE

LIFT

ER

LIFTER
SPE

ED

SPEED

PIER

CE

DEL

AY (s

ec)

0.5

1

2

3

0.75

0.25

0.1

AUTO

HT

FIND

HT

HI

LO

Figure 2-1 SC10 Standoff Control

The SC10 Standoff Control must be connected to the Re-
mote Control Accessory RC6010.

There is a connection available at the rear panel for con-
nection to the lifter motor. An internal jumper ribbon
cable also interfaces the unit to the Remote Control. The
inputs and outputs at these connections allow the vari-
ous parts of the system to be operated at one station.

A-00699

Standoff

Control Accessory

Lifter Motor

Remote

Control Assembly

Internal Jumper

Ribbon Cable

Remote

Control Cable

Power Supply

Assembly

Lifter Motor

Control Cable

Figure 2-2 Modular Remote System Configuration

2.03 Specifications & Design

Features

A. Standoff Control

The following applies to the Standoff Control Assembly
only.

1. System Compatiblility

The Standoff Control Accessory was designed to be
used with various Plasma Cutting Systems

Advertising