Section 3: installation procedures, 01 introduction, 02 site location – Tweco TD-750 Cutting Systems User Manual

Page 15: 03 unpacking, 04 mounting arc starter box, Section 3, Installation procedures

Advertising
background image

Manual 0-2475

11

INSTALLATION PROCEDURES

SECTION 3:

INSTALLATION

PROCEDURES

3.01 Introduction

This Section describes installation of the Arc Starter Box.
These instructions apply to the Arc Starter Box Assem-
bly only; installation procedures for the Plasma Power
Supply, Torch and Torch Leads, Options, and Accessories
are given in Manuals specifically provided for those units.

The complete installation consists of:

1. Site Selection

2. Unpacking

3. Mounting Arc Starter Box

4. Connecting Torch and Torch Leads

5. Operator Training

3.02 Site Location

Select a clean, dry location with good ventilation and ad-
equate working space around all components.

Review the safety precautions in the front of this manual
to be sure that the location meets all safety requirements.

3.03 Unpacking

Each component of the system is packaged separately and
protected with a carton and packing material to prevent
damage during shipping.

A. Unpacking Procedure

1. Unpack each item and remove all packing mate-

rial.

2. Locate the packing list(s) and use the list to iden-

tify and account for each item.

3. Inspect each item for possible shipping damage. If

damage is evident, contact your distributor and/or
shipping company before proceeding with system
installation.

3.04 Mounting Arc Starter Box

Mount the Arc Starter Box to the cutting table gantry per
the following procedure:

1. Remove the two screws securing the mounting bracket

to the Arc Starter Box.

A-00650

Two Screws And

External Star Washers

Mounting Bracket

Figure 3-1 Mounting Bracket Screw Removal

2. Slide the mounting bracket out of the two mounting

slots in the chassis of the Arc Starter Box.

CAUTION

The Arc Starter Box should be mounted as shown
to prevent coolant from dripping into the signal
connector of the quick disconnect when the torch
is disconnected.

3. Mount the bracket to the cutting table gantry using

any of the five holes provided in the mounting bracket.
It is recommended to use at least two mounting points.

NOTE

Refer to Appendix III for Mounting Hole Template.

A-00651

Four Mounting Bolts And

Washers (Customer Supplied)

Mounting Bracket

Figure 3-2 Mounting Bracket Installation