SERVICE

18

Manual 0-2475

• If voltage is less than 220 VDC proceed to Step 18.

18. In the Power Supply measure the voltage at the torch

bulkhead in the Power Supply (marked + and -).

• If greater than 220 VDC check for open connections

through the Power Supply connections, Torch
Leads Extension Assembly, and Arc Starter Box
input and output connections.

• If less than 220 VDC can be caused by a shorted

torch or torch leads.

• No voltage can be caused by the Pilot Control (PCR)

contactor in the Power Supply not closing. Refer
to the Power Supply Service Manual under symp-
toms of No Pilot.