Battery replacement 2, Thermometer functions, Operation guide dqr-300 – Casio DQR-300 User Manual

Page 4

Advertising
background image

Operation Guide DQR-300

4

Battery precautions

•

Keep batteries out of the reach of small children. If a battery is accidentally swallowed, contact your physician
immediately.

•

Be sure to load the batteries with their positive (+) and negative (–) ends facing correctly.

•

Never mix old and new batteries, or batteries of different brands.

•

Never charge the batteries that come with the clock.

•

Should batteries ever leak while in the clock, wipe out the fluid with a cloth, taking care not to let any get onto
your skin.

•

Replace the batteries at least once a year, even if the current batteries are working properly.

•

The batteries that come with the clock lose some of their power during transport and storage.

THERMOMETER FUNCTIONS

Both the main unit and the sub-unit are equipped with their own temperature sensors. Temperature data measured
by the sub-unit is sent by wireless transfer to the main unit. You can toggle the main unit display between the main
unit temperature reading and the sub-unit temperature reading. This makes it possible to view both the indoor and
outdoor temperature on the main unit display.

Temperature Measurements

•

Both the main unit and the sub-unit take temperature measurements every 16 seconds.

•

The temperature display shows “LO” for temperatures below –50

°

C (–58

°

F) and “HI” for temperatures above

70

°

C (158

°

F).

•

Though temperature readings are displayed up to 0

°

C (32

°

F) and greater than 41

°

C (105

°

F), note that such

readings are actually outside the guaranteed temperature range of this clock.

Switching between Celsius and Fahrenheit

•

Push the

°

C/

°

F button (

0

) to select either Celsius (

°

C) or Fahrenheit (

°

F).

Celsius (

°

C)

Fahrenheit (

°

F)

°

C/

°

F button

(0)

°C

°F

Switching between Main Unit and Sub-unit Temperature Data

•

Press the SELECT button (

B

) to toggle the display between the main unit (INDOOR) temperature and the sub-

unit (OUTDOOR) temperature.
Main unit temperature: INDOOR indicator displayed
Sub-unit temperature: OUTDOOR indicator displayed

•

The display does not change to the sub-unit (OUTDOOR) temperature if no data has been received from the sub-
unit yet.

•

Holding down SELECT button (

B

) for about two seconds causes the display to continually toggle between the

main unit and sub-unit temperature at five-second intervals.

Main unit

Sub-unit

SELECT button

(B)

INDOOR

OUTDOOR

High Temperature and Low Temperature Memory

•

The following data is stored in memory automatically.
Main unit high temperature and low temperature
Sub-unit high temperature and low temperature

•

To clear the high temperature and low temperature data memory, press the CLEAR button (

9

).

New data starts to be stored after memory is cleared.

CLEAR button (

9

)

MAX/MIN TEMP. button (

7

)

Main unit high temperature and low temperature

Sub-unit high temperature and low temperature

Current temperature and humidity

Advertising