3.18 Fiber Optic Cable Installation From DMC-3000 to DPC-3000
1.
Remove outer thin nuts from through hole protector at both ends of Fiber Optic Cable (L) that connects
between the DCM-3000 and DPC-3000.
CAUTION
Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced
into tight-radius turns.
2. Ensure that the outer protective hose/cable is exposed beyond the through hole protector approximately
1” and secure by tightening the wide nut with the rounded end while holding the other nut in place. Normal
hand tightening is not enough.
3. Feed the Fiber Optic Cable plug and wires through the back of each module (DMC-DPC) where indicated
and slide the thin nut back over the Fiber Optic Cable.
Fiber Optic for
DMC-3000 goes here
Art # A-09152_AB
Insert Fiber Optic cable here
Art # A-09153_AB