INSTALLATION

THERMAL ARC 161 S

Manual 0-5183

3-5

3-5

Installation

Figure 3-2: Setup for STICK (MMA) Welding

200A

Set Welding Current
as specified by the
Electrode Manufacturer.

Set Process Selection
Switch to STICK (MMA)

Positive Output
Terminal
(Dinse™ 50)

Negative Output
Terminal
(Dinse™ 50)

Art #: A-09914

3.06 STICK (MMA) Setup

STICK (MMA) Mode Sequence of Operation

CAUTION

Before any welding is to begin, be sure to wear all

appropriate and recommended safety equipment.

1. Switch the ON/OFF Switch (located on the rear panel)

to OFF.

2. Connect the ground clamp cable to the negative

output terminal, and the electrode holder cable to

the positive output terminal.

NOTE

This set up is known as DC Electrode Positive or

reverse polarity. Please consult with the stick electrode

manufacturer for specific polarity recommendations.

3. Connect the ground clamp to your workpiece.
4. Plug the power cable into the appropriate outlet,

and turn the switch to the “ON” position. The power

L.E.D light should illuminate.

5. Set the “Process Selection Switch” to STICK.
6. Set the weld current control knob to the desired

amperage.

7. Install a stick electrode in the electrode holder.
8. You are now ready to begin STICK Welding

NOTE

Gently strike the electrode on the work piece to

generate a welding arc, and slowly move along the

work piece while holding a consistent arc length

above base metal.