4.02 Welding Current Control

Explanation

32 Amp Outlet

The mains power 32 Amp circuit breaker or fuse should

not trip at this Weld Current value when STICK weld-

ing.
The environmental conditions that may cause the mains

power 32 Amp circuit breaker or fuse to trip are:

a) High ambient temperature

b) Worn parts in circuit breaker

c) Using an extension cable

d) Low line mains power voltage

Output Scale for 110V

The inside number scale identifies the avail-

able output weld current for STICK or LIFT TIG weld

modes.

STICK Mode:

Identifies the STICK weld point for

32 Amp outlet.

Exceeding these points will cause nui-

sance tripping of the circuit breaker or

fuse.

LIFT TIG Mode: A 32 Amp outlet is capable of supplying

enough input power for all LIFT TIG

output weld current values.

Nuisance tripping should not occur on a 32 Amp out-

let.
Output Scale for 230V

The outside number scale identifies the available output

weld current for STICK or LIFT TIG weld modes.
Nuisance tripping should not occur on a 32A 230V outlet

for both STICK & LIFT TIG Modes.

4.03 STICK (MMA) Electrode Polarity

Stick electrodes are generally connected to the "+" Posi-

tive Output Terminal and the work lead to the "−" Negative

Output Terminal but if in doubt consult the electrode

manufacturers literature for further information.