Tweco 400 TS Arcmaster User Manual

Page 28

Advertising
background image

21

7

Input Cable

The input cable connects the Primary supply voltage to the equipment.

8

SMART Logic Switch

Manual slide switch mounted on the back panel selects for proper input voltage. If this slide is not set
to the position that matches the input voltage from the electrical source the Smart Logic circuit will
inhibit welding power source output. The digital meter will show primary input error code.

9

Gas Inlet

The Gas Inlet is a 5/8 – UNF female gas fitting.

4.02 Weld Process Selection for ArcMaster 400 TS

Weld

Mode

Weld Process

Selection

STICK

HF

TIG

LIFT

TIG

Description

STD

Yes Yes Yes

2T operation in TIG Modes using remote
devices to control contactor & current.

SLOPE

No Yes Yes

4T operation in TIG Modes with crater fill
using a remote contactor device to
control sequence.

REPEAT

No Yes Yes

4T operation in TIG Modes with repeat
operation and crater fill using a remote
contactor device.

SPOT

No Yes No

2T operation spot welding in HF TIG using a
remote contactor device.

PULSE ON/OFF

No

Yes

Yes

Pulse operation in TIG Modes.

Contactor ON/OFF

Yes No Yes

Contactor operation in Stick and Lift
TIG Mode.

Operation

PANEL/REMOTE

Yes

Yes

Yes

Selects in operation Panel board or Remote.

Table 3 – Weld Process Selection verses Weld Mode for ArcMaster 400 TS