32
6.03 Save-Load Operation
A total number of 5 programs can be saved into the 400 TS memory.
SAVE
the Current Weld Parameters into Memory
• Press the
SAVE
button until the buzzer rings.
• Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter
• After selecting the desired memory location (ie 1 to 5), press the right scroll button and the machine will give
a beep to confirm the weld parameters from the control panel are saved.
LOAD
(retrieve) a Program to Control Panel
• Press the
LOAD
button until the buzzer rings.
• Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter. After selecting the
desired memory location (i.e. 1 to 5), press the right scroll button and the machine give a beep to confirm the
weld parameters are loaded onto the control panel