02 internal controls of a2281 remote, 02 internal controls of a2281 remote -7, Fabricator 281 – Tweco 281 Thermal Arc Fabricator User Manual

Page 45

Advertising
background image

FABRICATOR 281

April 10, 2006

4-7

Art # A-07463

(STITCH)

DWELL

BURNBACK

WELD (SPOT / STITCH)

t

MIN

5

7

12

3

2

4

6

8

9

10

11

t

MIN

1

5

7

9

3

2

4

6

8

t

WELD MODE

2T

SPOT STITCH

4T

(STITCH)

DWELL

BURNBACK

WELD (SPOT / STITCH)

t

MIN

5

7

12

3

2

4

6

8

9

10

11

t

MIN

1

5

7

9

3

2

4

6

8

t

WELD MODE

2T

SPOT STITCH

4T

Figure 4-5: Internal Welding Controls

WELD Mode Selector

The Weld Mode Selector switch selects the method of welding mode.

2T (Continuous Welding):

This mode of welding is used to weld two or more components together with a continuous weld. When the MIG
gun trigger switch is depressed welding commences. When the MIG gun trigger switch is released welding
ceases.

4.02 Internal Controls of A2281 Remote

Advertising