25. GUN CLAMP KNOB - Tighten this knob to

secure the welding gun to the wire feeder.

26. OUTPUT WIRE GUIDE - This guide is re-

quired to direct the welding wire from the drive feed
roll to the welding gun cable.

Power Source Compatibility:

Since the HEFTY

II

STAINLESS operates on arc

voltage, it will work with most constant current (CC)
or constant voltage (CV) DC-type power sources.

When connected to a HEFTY

II

STAINLESS, the

maximum allowed open circuit voltage (OCV) of the
power source is 100 VDC. Open circuit voltages
exceeding 100 VDC will damage or shorten the life
of the unit.

NOTE: Because of the high open circuit
voltage associated with most CC power

sources, it is recommended to place the

HEFTY

11

STAINLESS power switch in the

OFF position when not welding. This pro-
cedure will prolong the life of electrical com-
ponents connected to the power input lines.

When using the HEFTY

II

STAINLESS, there

must be at least 15 VDC between the output termi-
nals of the power source during standby and while
welding. Otherwise, the unit will not have enough
input voltage to operate properly.

A contactor is a standard component of the

HEFTY

II

STAINLESS and allows the welding wire

to remain electrically “cold” until the gun switch
trigger is depressed. This contactor is rated for 330
amps of welding current at a 60% duty cycle. If the
weld current or duty cycle rating is exceeded, the
contactor will be damaged or its life shortened.