3.03.02 Input Power

Each unit incorporates an INRUSH circuit and input voltage sensing circuit. When the MAIN
CIRCUIT SWITCH is turned on, the inrush circuit provides a pre-charging of the input capacitors.
SCR’s in the Power Control Assembly (PCA) will turn on after the input capacitors have charged
to full operating voltage (after approximately 5 seconds).

Note 3

Note the available input power. Damage to the PCA could occur if 460VAC or higher is
applied.

The following 208/230V Primary Current recommendations are required to obtain the
maximum welding current and duty cycle from this welding equipment:

Current & Duty Cycle

Model

Primary Supply

Lead Size

(Factory Fitted)

Minimum Primary

Current Circuit Size

(Vin/Amps)

TIG

STICK

230/29

208/32

185 @ 30%

230/38

-

Pro-Wave

185TSW

12/3 AWG

minimum

208/40

-

160 @ 40%

Table 2 – 208/230V Primary Current Circuit sizes to achieve maximum current