Tweco 500SP PowerMaster User Manual

Page 36

Advertising
background image

POWERMASTER 320SP, 400SP, 500SP

3-10

March 16, 2007

H. How To Refill The Cooling Fluid

Only use original MIG/TIG coolant for refill. It
provides protection against frost down to 4°F
(-20°C). If using other coolants, the coolant pump
could be damaged. Coolant circulation has to be
checked at regular intervals. Reliable coolant return
flow is essential to ensure the coolant is not lost and
the coolant cooled MIG torch is not damaged. Check
the level of the coolant every day before operating.
The coolant must be visible when the tank cap is
removed.

CAUTION

Remove the pin from the breather hole in
the cap of the coolant tank as leaving the
pin in the cap may cause a coolant flow
error.

MIG/TIG Coolant 1 Quart (1 L)

Part No. W4001402

MIG/TIG Coolant 1 Gallon (5 L) Part No. W4001400

MIG/TIG Coolant 5 Gallon (20 L) Part No. W4001401

I.

How To Configure The Power Supply
For Aluminum Welding

Change the feedrolls to U groove for aluminum wire
(refer to the Options and Accessories list in the
Appendix).

Change the torch liner to a nylon or teflon liner (refer
to the Options and Accessories list in the Appendix
and to the next section "3.07 Installing a New Wire
Conduit").

Use the correct size outlet guide to suit the wire
diameter.

.030 & .035 in. - Steel tube with red lining

.045 & 3/64 in. - Use steel tube with black lining

1/16 in. - Use clear teflon tube

Fasten the torch and insert the wire electrode.

NOTE

The parts required for the torch depends
on the type torch and

wire diameter.

Please refer to the torch spare parts list.

Art # A-06373

Coolant
Tank Cap

Advertising