GENERAL INFORMATION

2.01 Scope of this Manual

This manual provides operating instructions and basic
maintenance procedures for the Thermal Arc ULTIMA-
150

®

Plasma Welding Power Supply. Service of this equip-

ment is restricted to Thermal Dynamics trained person-
nel; unqualified personnel are strictly cautioned against
attempting repairs or adjustments not covered in this
manual, at the risk of voiding the warranty.

Read this manual thoroughly. A complete understanding
of the capabilities and functions of the equipment will
assure the dependable operation for which it was designed.

2.02 ULTIMA-150 Power Supply

Description

The ULTIMA-150 Plasma Welding Power Supply is one
integrated unit providing power, pilot control inverter, and
coolant recirculator. With output ranges from 0.5-15 amps
and 5-150 amps, the power supply is ideally suited for all
low current gas tungsten arc welding (GTAW) and auto-
mated welding applications. Suitable for use with all des-
ignated Thermal Dynamics plasma welding torches.

2.03 ULTIMA-150 Power Supply

Specifications

A. Input Power

200 VAC ±10%

50/60hz, 1 or 3 phase

208 VAC ±10%

50/60hz, 1 or 3 phase

230 VAC ±10%

50/60hz, 1 or 3 phase

380 VAC ±10%

50/60hz, 1 or 3 phase

415 VAC ±10%

50/60hz, 1 or 3 phase

460 VAC ±10%

50/60hz, 1 or 3 phase

575 VAC ±10%

50/60hz 3 phase (available with
optional Transformer Module
only)

B. Output Power

1. Output Amps

Range I - 0.5 to 15 amps DC Straight Polarity
Range II - 5 to 150 amps DC Straight Polarity

2. Duty Cycle

60% Duty Cycle @ 40ºC, 150 amp output
100% Duty Cycle @ 40°C, 100 amp output

3. Pilot Arc Output

2-15 amp Variable, Continuous Pilot Arc
Pilot Arc Output 100% Duty Cycle @ 40º C

C. Fuse

3A, 500V (1FU) Fuse

D. Protection Features

A number of interlocks have been to provided to assure
proper handling of fault conditions at all times.

• Coolant flow and level - Monitored and shut down

the recirculator pump when below minimum levels.

• Pump operation - System shuts down due to air in

torch leads or in the system.

• Coolant and power supply - Over temperature of the

power supply or coolant will immediately disable
the power supply output. The recirculator pump re-
mains running for system and coolant cool down.

• Plasma gas and shield gas - Both have minimum

pressure switches that disable pilot arc operation.

• Pilot arc - Always latched off in event of power sup-

ply interlock trip. The pilot must be disabled and
then re-energized to initiate the pilot arc after a fault
shutdown.

E. Gas Supply

Plasma Gas - 0.5-3.0 scfh

Shield Gas - 5.0-30 scfh

F. Coolant Reservoir Capacity

2 gallon Coolant Reservoir; Thermal Arc© Coolant
only

G. Weight

130 lbs (59 kg) - ULTIMA-150 Power Supply only

150 lbs (68kg) - shipping weight (including coolant
and torch)

H. Dimensions

18" high (457 mm) x 15" wide (381 mm) x 28.5" deep
(724 mm)

Advertising