Section 3: installation, 01 connections, 02 grounding – Tweco VA 4000 Ultra-Feed User Manual

Page 23: 03 emi considerations, Section 3, Installation -1, Ultrafeed va 4000

Advertising
background image

ULTRAFEED VA 4000

September 18, 2012

3-1

SECTION 3:

INSTALLATION

3.01 Connections

Refer to the System Outline drawing in the Appendix of
this manual for details.

1. Make the proper welding cable connections

between the power source and wire feeder and
between the power source and work connection.

2. Connect the control cable from the feeder to the

power source. Control cable extensions are
available; Refer to Available Options.

NOTE

An optional 870000-001 adapter cable will be
required for connection to a power source with
only a 5 pin amphenol connection and AC
voltage outlets. An optional 870093B-001
adapter cable will be required for connection
to a power source with only a 14 pin amphenol
connection. These options are only applicable
to 19 pin plug units.

3. Make the proper gas line connection from the gas

supply to the wire feeder gas valve (if gas will be
used).

4. Attach the welding gun to the wire feeder.

5. Connect the welding gun control leads to the wire

feeder gun switch terminals located on the front
of the feeder.

3.02 Grounding

To assure operator safety in the case of a fault condition,
the frame of the power source (welding machine) must
be grounded. The wire feeder sheet metal frame is
grounded only through pin G (for 19 pin plug) of the
control cable that connects to the power source.
Therefore, if the power source frame is not grounded,
then, the wire feeder sheet metal frame is not grounded,
and a shock hazard could possibly develop. Follow the
instructions found in the power source Owner’s Manual
for correct grounding methods.

3.03 EMI Considerations

Electromagnetic interference (EMI) is common in today’s
complex industrial environment. At times, EMI levels can
become great enough to affect the operation of the
machinery. To help reduce and safeguard against EMI
levels in the welding area, follow these simple guidelines:

1. Firmly secure all sheet metal panels on the power

source and wire feeder. Repair or replace heavily
corroded or damaged panels and/or fasteners.

2. Keep the welding cables and control cables as

short as possible.

3. Route the ‘+’ and ‘-’ welding cables from a

particular power source together.

4. Keep the welding cables as straight as possible;

avoid coiling up the cables.

5. Route the control cable away from the welding

cables.

NOTE

Grounding of the workpiece may reduce
emissions in some, but not all circumstances.
To prevent the risk of injury or damage to other
electrical equipment when grounding the
workpiece, take care to follow all local laws
and regulations.

Advertising